Manageable power strip IP function monitoring the environmental conditions in the cabinet.

 

Provides full control and management of hardware resources via the Internet. It allows, power management and monitoring of temperature, humidity, power consumption, power consumption, devices installed in distribution racks and other applications where electronic equipment is used to maintain continuous operation of IT systems.

 

Functions of the device:

 

  • Switching the power supply to devices from a web browser (manually or automatically, according to defined parameters or RTC settings)

     

  • Resetting devices (after clicking the RESET button, the corresponding socket switches off for a defined period of time, then switches itself on. This function is used to reset devices that are also responsible for communication with the strip)

     

  • Alarming (after exceeding established temperature thresholds, loss of 230V power supply or violation of one of the two binary inputs, Power-Service can alarm with a sound signal and send an e-mail or SNMP,

     

  • Monitoring and control - temperature, status of inputs, power measurement

     

  • Archiving (PZZ-5C3E cooperates with PMServer platform enabling data archiving and presenting parameters in the form of on-line and archival charts, information on alarms, supporting up to 128 devices)

     

Modes of operation:

 

  • a - manual : in this mode we can control the sockets by using on/off switches and performing a time specific reset. Reset allows us to cut off the power for 5 seconds from a network device (e.g. switch in which one of the ports failed) to which the Power-Service is also connected. In this mode it is possible to control outputs by means of inputs, thresholds of measured values, other alarms. The reset and DAP functions do not work.

     

Logic:

 

There are two logic functions that we can realize on the outputs:

 

  • a - OR - in this mode at least one condition (temperature threshold, other input) must be satisfied to drive the output.

     

  • b - AND - in this mode all conditions (temperature threshold, other input) must be satisfied to drive the output.

     

DAP: ( Down After Power UP )

 

  • This function works in manual mode, it sets the state of the output sockets in OFF position, after the return of the supply voltage ( function mostly used for heaters or lighting )

     

 

 

 

Technical Specifications

TECHNICAL DATA
Height/width/depth 1U / 19 / 75mm ( 0U - when mounted vertically )
Standards and Protocols IEEE 802.3i 10Base-T, TCP/IP, UDP HTTP, SMTP, DNS, DHCP, SNMP
Certifications and approvals CE
PORTS AND SLOTS
Power output 5 x IEC C13 female, 3 x CEE 7/5 (momentary.8A230VAC/socket, continuous.6A230VAC/socket, max.12A 230VAC/leaf)
Power connector 1 x IEC C14, C20, E, Schuko (16A 230VAC + fuse)
Input 1-wire 1 x RJ12 (temperature sensor, humidity sensor)
Digital input NO/NC 2 x TBW-3.5 (additional 12V power line)
POWER SUPPLY
Control module 90 230V AC
Power outputs 12-24 230V AC/DC (option)
Rated current consumption 150 mA
WORKING ENVIRONMENT
Permissible operating temperature 0°C ÷ 45°C
Permissible ambient humidity

10% ÷ 90% non-condensing

 

 