Non sensitive elements (NON-SE) intended:  to connect TRIBO-S processing unit with sensitive element; pass the gates or building in the line with fence; arrange specialforteza europe detection zone for the best integration of TRIBO-S with CCTV  system.
1. PURPOSE

Non sensitive element is a part of the TRIBO-S fence protection system which is not sensitive for deformation and vibration. It is using to transmit signals between TRIBO-S unit and sensitive element or connect SE-86 with SE-86 using connection sleeves.

2. GENERAL INFORMATION
Non sensitive element max. length in one input channel of TRIBO-S processing unit is 300 meters, it can be interchange with SE-86  to NON-SE to SE-86.
Non sensitive elements isolation is not protected from the outside weather conditions so the element must be protected with plastic corrugated tube when mounted on the fence or underground.

3. LAYING OF NON SENSITIVE ELEMENT
TRIBO-S processing unit installation near the fence.
Variant where TRIBO-S processing unit installed near the fence (in security room) at distance from the protected fence were sensitive elements is mounted. In this variant with one TRIBO-S processing unit we can protect up to 600 meters of the fence. The maximum length of sensitive element and non-sensitive for one detection zone is SE-86 300 meters NON-SE 300 meters.
Tribo-M processing unit instalaton near the fence
Requirement for TRIBO-S system „one detection zone up to 50 meters“ for integration with CCTV system.
Variant where requirement for TRIBO-S system to give alarms in different detection zones lengths. Detection zone can be from 1 meter up to 300 meters. Below you see the drawing were requirement was to have alarm from detection zone 50 meters, 2 lines of sensitive element it is standard for 2 meters high fence.

TRIBO-M system one detection zone up to 50 meters
Using NON-SE element to pass gates and buildings.
Variant where in detections zone is a gates and buildings. Using connection sleeves and non-sensitive element we can arrange the non-sensitive gaps in detection zone. In this option we use connection sleeve to connect SE-86 with NON-SE, using the protection pipe lay the NON-SE element under the entries road and using the connection sleeve connect NON-SE with SE-86 on the fence. So the same detection zone before gate and after. For gate protection we offer to use FMC 10 (50) or FMC 24 (50).

Non sensitive element pass gates and buildings