P32 is a new generation control panel with everything you need for the protection of an apartment, office, individual house or homestead. Compared to PAS series control panels, the P series is equipped with a 2-wire smoke detector control circuit, a wireless sensor signal reception module and the ability to safely connect or change communicators. See the Additional Information table for more technical information.
Specifications
Features | P32 |
Alarm system concept | Hybrid modular system |
On-board wired zones |
7/14 (doubling) |
2-wire smoke detector input | 1 |
On-board wireless zones | 32 |
Maximum zones in system | 32 |
On-board PGM | 3 |
Maximum PGM in system | 16 |
User + installer codes | 31+1 |
Duress code |
X1, X2, X3, X4 (when X4 = X4 + 1) |
Defaulting user code | Yes |
Key switch zone | Yes |
Partitions | 4 |
Shared partition (common area) | Yes |
System timers | 16 |
Maximum keypads/modules in system | 15 |
Keypad compatibility | All SECOLINK keypads |
Event log buffer | 512 |
PSTN communicator | Plug-on |
In-built interface for backup communicator | TTL Serial |
Data bus protocol | KRBUS |
Total phone numbers: CMS reporting + personal dialing | 9 |
Maximum phone numbers for personal dialing | Up to 5 |
Maximum phone numbers for CMS reporting | Up to 4 |
Reporting protocol | Contact ID |
Voice guide for system control over PSTN | Yes |
Voice guide for system programming over PSTN | Yes |
Roller detector type | Yes |
Vibration detector type | Yes |
Vibration zone speed (sensitivity) | 0.01 - 0.25 sec. |
Normal zone speed (sensitivity) | 0.1 - 2.5 sec. |
Zone loop (detector) type | NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL, Vibration, Roller |
Arming mode | Away, Max Away, Night, Stay. |
Zone definition |
Entry/exit, entry/exit forced, interior, interior night armed, follower, follower night armed, perimeter, instant, PGM control 24h: burglary, panic silent, panic audible, tamper, fire, smoke, fire button, medical button, fire supervisory, low water level, RF Jam, gas detected, water leakage, high temperature, low temperature |
Zone attributes | Enable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm, armed night |
PGM definition | Fire alarm, fire/burglary alarm, burglary alarm, tamper alarm, technical alarm, selected alarms, chime, zone violation, bypass status, selected trouble, exit/entry warning, exit/arm status, full arm status, power supply, resettable power supply, fire power supply, timer, mono/bi switch |
PGM attributes | Inversion, pulsation, latch, pre-alarm, arm notification, arming failure notification, disarm notification, clear alarm notification, armed in specific mode |
Rated voltage of power supply (AC) | ~20 V |
Minimum AC voltage (note: ~16 V input voltage lets control panel to generate max 0.7 A output current) |
~16 V |
Maximum AC voltage (Note: higher than ~22 V voltage can damage control panel) |
~22 V |
Maximum long term output current of control panel (I+AUX + I+BELL + I+PGM + battery charge): |
≤2.0 A |
Maximum current of slow blowing fuse used in primary AC | 250 mA |
Maximum AC power consumption | 150 mA |
Minimum voltage on +AUX, +BELL, +PGM outputs | 12 V |
Maximum voltage on +AUX, +BELL, +PGM outputs | 13.9 V |
Maximum current out of +AUX | +1 A |
Maximum current out of +BELL | +2 A |
Maximum current into -PGM | -0.3 A |
Maximum current out of +PGM | +0.9 A |
Short circuit, overload protection of +BELL, +PGM, +AUX | Electronic |
Battery charge, +BELL, +AUX current measurement | Yes |
Failed (waste) backup battery disconnection | Yes |
Maximum battery charging current | 0.35 A |
Maximum current of fast blowing fuse used in battery circuit | 3.15 A |
Control panel disconnect battery when it’s voltage less than | 9.5 V |
Recommended backup battery | 12 V, 7 Ah / 20 Hr |
Operational compliance | +EN50131, Grade2 |
Overall dimensions W x H in mm | 145 x 77 |
Environmental compliance | ROHS |
Operating temperature | -10oC up to +50oC |
Production status |
In production |
Latest firmware version |
v0.03 |
In-field firmware upgrade (by USB) | Yes |
Features | P64 |
Alarm system concept | Hybrid modular system |
On-board wired zones | 7/14 (doubling) |
2-wire smoke detector input | 1 |
On-board wireless zones | 64 |
Maximum zones in system | 64 |
On-board PGM | 3 |
Maximum PGM in system | 16 |
User + installer codes | 63+1 |
Duress code |
X1, X2, X3, X4 (when X4 = X4 + 1) |
Defaulting user code | Yes |
Key switch zone | Yes |
Partitions | 4 |
Shared partition (common area) | Yes |
System timers | 16 |
Maximum keypads/modules in system | 15 |
Keypad compatibility | Only KM24G |
Event log buffer | 512 |
PSTN communicator | Plug-on |
In-built interface for backup communicator | TTL Serial |
Data bus protocol | KRBUS |
Total phone numbers: CMS reporting + personal dialing | 9 |
Maximum phone numbers for personal dialing | Up to 5 |
Maximum phone numbers for CMS reporting | Up to 4 |
Reporting protocol | Contact ID |
Voice guide for system control over PSTN | Yes |
Voice guide for system programming over PSTN | Yes |
Roller detector type | Yes |
Vibration detector type | Yes |
Vibration zone speed (sensitivity) | 0.01 - 0.25 sec. |
Normal zone speed (sensitivity) | 0.1 - 2.5 sec. |
Zone loop (detector) type | NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL, Vibration, Roller |
Arming mode | Away, Max Away, Night, Stay. |
Zone definition |
Entry/exit, entry/exit forced, interior, interior night armed, follower, follower night armed, perimeter, instant, PGM control 24h: burglary, panic silent, panic audible, tamper, fire, smoke, fire button, medical button, fire supervisory, low water level, RF Jam, gas detected, water leakage, high temperature, low temperature |
Zone attributes | Enable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm, armed night |
PGM definition | Fire alarm, fire/burglary alarm, burglary alarm, tamper alarm, technical alarm, selected alarms, chime, zone violation, bypass status, selected trouble, exit/entry warning, exit/arm status, full arm status, power supply, resettable power supply, fire power supply, timer, mono/bi switch |
PGM attributes | Inversion, pulsation, latch, pre-alarm, arm notification, arming failure notification, disarm notification, clear alarm notification, armed in specific mode |
Rated voltage of power supply (AC) | ~20 V |
Minimum AC voltage (note: ~16 V input voltage lets control panel to generate max 0.7 A output current) |
~16 V |
Maximum AC voltage (Note: higher than ~22 V voltage can damage control panel) |
~22 V |
Maximum long term output current of control panel (I+AUX + I+BELL + I+PGM + battery charge): |
≤2.0 A |
Maximum current of slow blowing fuse used in primary AC | 250 mA |
Maximum AC power consumption | 150 mA |
Minimum voltage on +AUX, +BELL, +PGM outputs | 12 V |
Maximum voltage on +AUX, +BELL, +PGM outputs | 13.9 V |
Maximum current out of +AUX | +1 A |
Maximum current out of +BELL | +2 A |
Maximum current into -PGM | -0.3 A |
Maximum current out of +PGM | +0.9 A |
Short circuit, overload protection of +BELL, +PGM, +AUX | Electronic |
Battery charge, +BELL, +AUX current measurement | Yes |
Failed (waste) backup battery disconnection | Yes |
Maximum battery charging current | 0.35 A |
Maximum current of fast blowing fuse used in battery circuit | 3.15 A |
Control panel disconnect battery when it’s voltage less than | 9.5 V |
Recommended backup battery | 12 V, 7 Ah / 20 Hr |
Operational compliance | +EN50131, Grade2 |
Overall dimensions W x H in mm | 145 x 77 |
Environmental compliance | ROHS |
Operating temperature | -10oC up to +50oC |
Production status | In production |
Latest firmware version | v0.03 |
In-field firmware upgrade (by USB) |
The KM24G is a high-end control panel suitable for all SECOLINK security systems with up to 64 security sensors and up to 63 users. Compared to the KM24A console, KM24G notifies you of events by voice, has an information text bar and a system programming wizard for the convenience of installers.
Features | KM24G |
Product type | Alarm system module |
On-Board zones |
2 |
On-Board PGM |
1 (open collector up to 15 mA) |
Ambient temperature measurement |
Yes |
LCD type |
Graphic: 240 x 120 dots |
Keys in keypad | 24 |
Programmable fast keys (F-Keys) | 32 |
Data bus protocol | KRBUS |
Zone loop (detector) type | NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL |
Maximum wiring distance to CP | 300 m |
Power supply | 9 - 14 V |
Voltage measurement on keypad | Yes |
Current consumption |
Backlight on 80 mA, Backight off < 68 mA. |
On-Board sounder | Speaker |
Backlight color |
Display = blue, keypad = blue |
Character set | Major character sets of the world. |
User interface type | Navigation menu with short help text system. |
Overall dimensions W x H in mm | 92 x 133 |
Environmental compliance | ROHS |
Operating temperature |
0oC up to +50oC |
Interface for keypad settings programming | USB |
Interface for keypad firmware updating |
USB |