P16, P32, P64 are a new generation of control panels with everything you need for the protection of an apartment, office, individual house or homestead. Compared to the PAS series control panels, the P series is equipped with a 2-wire smoke detector control circuit, a wireless sensor signal reception module and the ability to safely connect or change communicators. See the table below for more technical information.

Specifications

Features P32
Alarm system concept Hybrid modular system
On-board wired zones

7/14 (doubling)

2-wire smoke detector input 1
On-board wireless zones 32
Maximum zones in system 32
On-board PGM 3
Maximum PGM in system 16
User + installer codes 31+1
Duress code

X1, X2, X3, X4 (when X4 = X4 + 1)

Defaulting user code Yes
Key switch zone Yes
Partitions 4
Shared partition (common area) Yes
System timers 16
Maximum keypads/modules in system 15
Keypad compatibility All SECOLINK keypads
Event log buffer 512
PSTN communicator Plug-on
In-built interface for backup communicator TTL Serial
Data bus protocol KRBUS
Total phone numbers: CMS reporting + personal dialing 9
Maximum phone numbers for personal dialing Up to 5
Maximum phone numbers for CMS reporting Up to 4
Reporting protocol Contact ID
Voice guide for system control over PSTN Yes
Voice guide for system programming over PSTN Yes
Roller detector type Yes
Vibration detector type Yes
Vibration zone speed (sensitivity) 0.01 - 0.25 sec.
Normal zone speed (sensitivity) 0.1 - 2.5 sec.
Zone loop (detector) type NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL, Vibration, Roller
Arming mode Away, Max Away, Night, Stay.
Zone definition

Entry/exit, entry/exit forced, interior, interior night armed, follower, follower night armed, perimeter, instant, PGM control

24h: burglary, panic silent, panic audible, tamper, fire, smoke, fire button, medical button, fire supervisory, low water level, RF Jam, gas detected, water leakage, high temperature, low temperature

Zone attributes Enable bypass, no alarm, arm when door is closed, entry route, exit route, fire verification, limitation of alarms, limitation of reporting, pre-alarm, armed night
PGM definition Fire alarm, fire/burglary alarm, burglary alarm, tamper alarm, technical alarm, selected alarms, chime, zone violation, bypass status, selected trouble, exit/entry warning, exit/arm status, full arm status, power supply, resettable power supply, fire power supply, timer, mono/bi switch
PGM attributes Inversion, pulsation, latch, pre-alarm, arm notification, arming failure notification, disarm notification, clear alarm notification, armed in specific mode
Rated voltage of power supply (AC) ~20 V

Minimum AC voltage

(note: ~16 V input voltage lets control panel to generate max 0.7 A output current)

~16 V

Maximum AC voltage

(Note: higher than ~22 V voltage can damage control panel)

~22 V

Maximum long term output current of control panel

(I+AUX + I+BELL + I+PGM + battery charge):

≤2.0 A
Maximum current of slow blowing fuse used in primary AC 250 mA
Maximum AC power consumption 150 mA
Minimum voltage on +AUX, +BELL, +PGM outputs 12 V
Maximum voltage on +AUX, +BELL, +PGM outputs 13.9 V
Maximum current out of +AUX +1 A
Maximum current out of +BELL +2 A
Maximum current into -PGM -0.3 A
Maximum current out of +PGM +0.9 A
Short circuit, overload protection of +BELL, +PGM, +AUX Electronic
Battery charge, +BELL, +AUX current measurement Yes
Failed (waste) backup battery disconnection Yes
Maximum battery charging current 0.35 A
Maximum current of fast blowing fuse used in battery circuit 3.15 A
Control panel disconnect battery when it’s voltage less than 9.5 V
Recommended backup battery 12 V, 7 Ah / 20 Hr
Operational compliance +EN50131, Grade2
Overall dimensions W x H in mm 145 x 77
Environmental compliance ROHS
Operating temperature -10oC up to +50oC
Production status

In production

Latest firmware version

v0.03

In-field firmware upgrade (by USB) Yes

 

KM24, KM24A are mid-to-high-end control panels with a graphic LCD screen. They are suitable for all SECOLINK security systems with up to 32 security sensors. KM24 series control panels are recommended when the security system uses the SECOLINK GSM or LAN module. With the help of this series of consoles, it is easy for the user to set up the messages they want to receive on the mobile phone.

Specifications

Features KM24A
Product type Alarm system module
On-Board zones

2

On-Board PGM

1 (open collector up to 15 mA)

Ambient temperature measurement

Yes

LCD type

Graphic:

128 x 64 dots

Keys in keypad 24
Programmable fast keys (F-Keys) 32
Data bus protocol KRBUS
Zone loop (detector) type NC, NO, NC/EOL, NO/EOL, NC/DEOL, NO/DEOL
Maximum wiring distance to CP 300 m
Power supply 9 - 14 V
Voltage measurement on keypad Yes
Current consumption

Backlight on 80 mA,

Backight off < 68 mA.

On-Board sounder Speaker

Backlight color 

Display = blue, keypad = blue
Character set Major character sets of the world.
User interface type Navigation menu with short help text system.
Overall dimensions W x H in mm 92 x 133
Environmental compliance ROHS
Operating temperature

0oC up to +50oC

Interface for keypad settings programming USB

Interface for keypad firmware updating

USB